Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort .
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
A22RW-2AG-24A-11
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on A22RW-2AG-24A-11.
Connectors with Cables are UL certified .
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Power supply: DC.
Output type: PNP.
Measurable at any position.
The usual limitations, such as the ''measurement,
area being confined to the center''
or ''large errors due to positioning'',
that used to plague laser measuring sensors,
have now been overcome. Measurements can be,
consistently taken within a 500 mm area,
whatever stage the work is at or whichever way it is inserted A22RW-2AG-24A-11.
It can now be set to positions without interference from,
the work feed and without limitations of size of work area. Type: Normal wiring.
Cable length L: 5.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. High voltage ground relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high reliability.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of the specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate.
In all the models set up alarm terminal.
Appearance: Round/Half-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-H.
Output: SPST-NO + SPST-NO.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring). A22RW-2AG-24A-11.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type A22RW-2AG-24A-11.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
A22RW-2AG-24A-11 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22RW-2AG-24A-11&select=5