OMRON A22RW-2AG-24A-01
Size: 48 x 96mm.
Control output 1: current.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications .
Can be set up to 8 procedures (mode) x 32 (step) procedure A22RW-2AG-24A-01.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility A22RW-2AG-24A-01
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set A22RW-2AG-24A-01.
It can be easily set by CX-Thermo (sold separately) .
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control A22RW-2AG-24A-01. Name: Cameras, Cameras with Intelligent Light Source and Lens.
Easy-to-use Windows®-based software that can provide,
more sophisticated functionality and capability to the,
F150-3 using a drag-and-drop, flow-chart like setup envi,
ronment requiring no programming skills. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV A22RW-2AG-24A-01.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation A22RW-2AG-24A-01.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
A22RW-2AG-24A-01 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=A22RW-2AG-24A-01&select=5


...more relevant model market price >>>>
Related products
OMRON
Pushbutton Switch
A22L-DG-24A-01M
OMRON Pushbutton Switch A22L-DG-24A-01M
Appearance: Square/Projection type LED l
OMRON
Knob-type Selector Switch
A22W-2MG-24A-01
OMRON Knob-type Selector Switch A22W-2MG-24A-01
Appearance: Kno-type Selector Switch A2
OMRON
Pushbutton Switch
A22L-TG-24A-01A
OMRON Pushbutton Switch A22L-TG-24A-01A
Appearance: Round/Projection type LED li
OMRON
Pushbutton Switch
A22L-GG-24A-01M
OMRON Pushbutton Switch A22L-GG-24A-01M
Appearance: Round/Full-guard type LED li