LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
A22RL-FA-T2-11M
No PHOTO
OMRON A22RL-FA-T2-11M
Actuator: Roller lever: R63.
Indicator: Neon lamp.
Item: Basic.
Pretravel (PT): 15±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches .
Standard-feature gold-clad crossbar contacts provide high reliability A22RL-FA-T2-11M
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models A22RL-FA-T2-11M. Material: N10276 (See note) .
Weight (g): Approx. 190.
Material indication lines: 4 lines.
A Wide Variety of Electrodes for Long Lasting.
Reliability.
Standard Electrodes are made of stainless steel (SUS 304) and,
can be used in applications for purified water.
SUS316 Electrodes can be used in applications where resistance,
to corrosion is required. Titanium and HAS Electrodes can be,
used in applications where resistance to acid is required A22RL-FA-T2-11M.
For applications where long electrodes are required, a connection,
nut and two Lock Nuts can be used to extend the electrodes 1 m,
at a time. Number of beams: 41.
Protective height: 1020mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternatee,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV A22RL-FA-T2-11M.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs A22RL-FA-T2-11M.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A22RL-FA-T2-11M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=A22RL-FA-T2-11M&select=5


...more relevant model market price >>>>
Related products
OMRON
Pushbutton Switch
A22L-DY-T2-11M
OMRON Pushbutton Switch A22L-DY-T2-11M
Appearance: Square/Projection type LED v
OMRON
Pushbutton Switch
A22L-DG-T2-11M
OMRON Pushbutton Switch A22L-DG-T2-11M
Appearance: Square/Projection type LED v
OMRON
Pushbutton Switch
A22L-HG-T2-11M
OMRON Pushbutton Switch A22L-HG-T2-11M
Appearance: Round/Half-guard type LED vo
OMRON
Pushbutton Switch
A22L-TR-T2-11M
OMRON Pushbutton Switch A22L-TR-T2-11M
Appearance: Round/Projection type LED vo