Operating method: Incrementing, decrementing, and reversible (UP/DOWN A to F).
Mounting method: Flush mounting.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Memory backup: No.
Display: Yes (8-mm high 7-segment LED).
Models: 6 digits.
A DIN 72 x 72 mm Best-selling Counter .
Easy setting with thumbwheel switches A22L-TG-24A-11M.
A draw-out construction enables maintenance without rewiring
A22L-TG-24A-11M
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Sensing method: Retro-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired A22L-TG-24A-11M.
Sensing distance: 7 m.
Functions: -- .
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points A22L-TG-24A-11M.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use .
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Appearance: Round/Half-guard type LED lighting,
(without Voltage Reduction Unit) A22L-H.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring)) A22L-TG-24A-11M.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type A22L-TG-24A-11M.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
A22L-TG-24A-11M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-TG-24A-11M&select=5