Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function .
Event entry point: 2.
Transfer output: - A22L-HR-T2-20A.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved
A22L-HR-T2-20A
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) A22L-HR-T2-20A.
High speed sampling period 60ms .
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) A22L-HR-T2-20A.
Setting the program settings that can perform flexible contact output .
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation. Easy Setting Using DIP Switch and Simple.
Functions in DIN 48 × 48 mm-size Temperature.
Controllers.
Easy setting using DIP switch.
Models with two alarms added to Series, ideal for temperature,
alarm applications.
Universal-input (thermocouple/platinum resistance thermometer),
models also available.
Clearly visible digital display with character height of 13.5 mm.
Models available with black in addition to white cases.
RoHS compliant. Easy temperature and humidity control with an SD Card. Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvolltages and,
undervoltages A22L-HR-T2-20A.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssuppported A22L-HR-T2-20A.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
A22L-HR-T2-20A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A22L-HR-T2-20A&select=5