Item: Operation indicator (LED) *1; High-precision 5°.
Actuator: Roller lever, direct-wired connector; 2 conductors; AC.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches A16L-TRM-24-1.
Standard-feature gold-clad crossbar contacts provide high reliability
A16L-TRM-24-1
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models A16L-TRM-24-1. Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.180 A; 60 Hz, 0.160 A .
Rated input: 50 Hz, 12 W; 60 Hz, 10 W.
Rated rotational speed: 50 Hz, 2800 r/min; 60 Hz, 3300 r/min.
Maximum flow rate: 50 Hz, 0.80 m3/min; 60 Hz, 0.90 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 58 Pa A16L-TRM-24-1.
Noise: 50 Hz, 37 dB; 60 Hz, 40 dB .
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Used for data input and process value display for the C200H-TC---, C200H-TV---, C200H-CP114, and C200H-PID0-.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
haave enabled major savinngs in cost and space compared,
with previous systems A16L-TRM-24-1.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems A16L-TRM-24-1.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
A16L-TRM-24-1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A16L-TRM-24-1&select=5