Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Automatic.
Output: SPST-NC + SPST-NC.
Operating voltage: 200 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia . or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit A16-JWM-1.
Finger protection mechanism on Switch Unit provided as a standard feature
A16-JWM-1
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models) A16-JWM-1. Measurement range: 5 mm .
Resolution: 0.5 µm.
Operating force: 5 N max.
Five Types of Sensor for Use in a Wide.
Range of Environments.
D5SN-S01/-S04/-S04-L Sensors have a compact and light,
weight design with an ultra-small diameter of 6 mm.
The D5SN-S01 offers a high resolution of 0.1 µm.
D5SN-M05/-M10 Sensors have a robust construction and can,
withstand a horizontal load of 5 N A16-JWM-1.
D5SN-S01/-S04/-M05/-M10 Sensors ensure IP67 degree of,
protection .
All Sensors have an insulated design. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to ssee the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV A16-JWM-1.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation A16-JWM-1.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
A16-JWM-1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=A16-JWM-1&select=5