The communication unit can connect the multi function small transducer EtherCAT to the MX2 network.
The communication unit passed the EtherCAT conformance test.
Power supply: through the inverter power supply.
Protection structure: open type (IP20). Type: 1a1b welding terminal.
Shape: square.
Type: General load .
Action: instantaneous action (auto recovery) NX-EC0142.
With light: LED with light.
Using voltage: DC12V
NX-EC0142
Operation Department color: red.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Temperature range: 0°C to 100°C.
A Wide Variety of High-precision.
Temperature Sensors NX-EC0142.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work .
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Supply voltage: 12 VDC NX-EC0142.
Control output: Contact output, SPDT (time-limit SPDT) .
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M. Appearance: Shielded, 5.4 dia.
Stable sensing area: 1 (2) mm.
Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C. Due to the use of the SYSNET link unit,
Making the N:N maximum capable of connecting 126 sets of PC communications becomes possible,
High speed long distance optical cable.Appearance: ADR shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advannced technology of fuzzy innference to make the protection and coordination of digital DCR NX-EC0142.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme NX-EC0142.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.
NX-EC0142 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=NX-EC0142&select=5