Improved update. Reduce standby power consumption, and then achieve lightweight.
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance .
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible
MS3057-12A
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
Type: G3N type, both full of water, water shortage alarm function of automatic supply and drainage MS3057-12A.
Package product name: 61F-G3N base * 1, 61F-11_ unit * 3.
Purpose: General use. Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 1.1 m3/min; 60 Hz, 1.3 m3/min MS3057-12A.
Maximum static pressure: 50 Hz, 67 Pa; 60 Hz, 63 Pa .
Noise: 50 Hz, 45 dB; 60 Hz, 48 dB.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 300W.
Output voltage: 12V.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock MS3057-12A.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when thhe fan is replaced by the customer MS3057-12A. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
")
MS3057-12A Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MS3057-12A&select=5