Sensing distance: (See note 2.)0 to 3.5 mm(pressed position) (See note 1.).
Sensing method: Pushbutton.
Operation mode: ON with no load.
Cable length: 1 m.
Model: PNP output .
Using a pushbutton enables,
accurately detecting difficult-to-detec objects.
Conforms to standards for semiconductor FOUP cassettes to ena,
accurately detecting FOUP cassettes without being affected by the,
material, color, or reflectance of the bottoms of the cassettes
MM3XP DC200/220
Thin design enables mounting in a wider range of applications, e.g.,
on transfer arms.
Increased visibility with 4-direction indicator.
Optical detection of actuator operation provides a long life,
(mechanical life: 5 million operations min MM3XP DC200/220. ).
Models available with PNP or NPN output.
Models are available with very flexible robot cable. Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ MM3XP DC200/220.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, 2-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 4 points: Pulse voltage (2 points) and,
Pulse voltage/current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible wwith a single Controlller MM3XP DC200/220.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
rooot calculation and broken-line approximation) MM3XP DC200/220.