Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function MM2PN AC24.
Indication Accuracy.
Thermocouple input: ±0
MM2PN AC243% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV MM2PN AC24.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Number of beams: 92.
Protective height: 1,870mm.
Model: NPN.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO MM2PN AC24.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Type: printing plate mounting type, with left column.
Driving rod: long swing rod type.
Terminal specification: printed board, angular.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Supported.
Load power supply voltage: 400 to 480 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross.
SSRs. (See note.).
One Controller can control up to 8 SSRs.
RS-485 communications to set manipulated variabbles and,
heater burnout detection MM2PN AC24. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for1550--A current detection MM2PN AC24.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used.
MM2PN AC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MM2PN AC24&select=5