Actuator: Sealed (Booted); Sealed plunger; DC.
Mounting: Base mounting.
General-purpose Enclosed.
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches MKS2XTIN-11 DC24. DC models have also been added,
to the series
MKS2XTIN-11 DC24
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard) MKS2XTIN-11 DC24.
(Ask your OMRON representative for information on approved models.)Actuator: Short hinge lever.
Type: Standard.
Compact, General-purpose Horizontal.
Switches.
Models for Microloads Added to Series.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.),
Incorporates a switch with a durable coil spring in a tough,
high precision case MKS2XTIN-11 DC24.
Compact and uses a single basic switch for applications where,
strength is required.
Models for microloads and models with operation indicators,
added to series.
Terminal protective cover can be switched to wire cable from,
either the left or right.
Sealing characteristics that meet IEC IP67 degree of protection. Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Connector (M12).
Sensing distance: 100 mm (wide view).
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A(200 VAC).
Alarm output *2: Sinking/sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that MKS2XTIN-11 DC24.
conform to UUL Class 2 Output standards .
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) MKS2XTIN-11 DC24.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
MKS2XTIN-11 DC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS2XTIN-11 DC24&select=5