Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns MKS2PIN AC120.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
MKS2PIN AC120
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection MKS2PIN AC120. Input type: NPN/ voltage pulse input type .
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Transistor: -; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display MKS2PIN AC120.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
The cumulative pulse input is 50kHz, the phase difference pulse is 25kHz, and the increase or decrease of pulse isAppearance: Round/Projection type LED lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Rinng) MKS2PIN AC120.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type MKS2PIN AC120.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
MKS2PIN AC120 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS2PIN AC120&select=5