Power rating: 150 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 15 V VDC.
Output current: 10 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost .
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation MKS2P-V AC100.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage
MKS2P-V AC100
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty MKS2P-V AC100.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications .
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A) MKS2P-V AC100.
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: SPDT.
Lighting: Chameleon; 24 VDC.
Pushbutton color symbol: 1.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Output: SPDT.
Lighting: LED.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater controll methods,
including OON/OFF control, phase control, and cyclic control MKS2P-V AC100.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads MKS2P-V AC100.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
MKS2P-V AC100 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MKS2P-V AC100&select=5