No. of notches: 2 notches.
Output: SPDT.
Reset method: Manual.
Lighting method: LED.
Separate Construction with Cylindrical.
16-dia. Body.
Same separate construction as the A16-series Pushbuttons with,
Miniature Design of 28.5 mm.
The same contacts can be used for both standard loads and,
microloads .
Oil-resistant IP65 models,
Conforms to EN60947-5-1 MK3P-I DC125. Number of beams: 56.
Protective height: 1120mm
MK3P-I DC125
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A MK3P-I DC125.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module .
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin) MK3P-I DC125.
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC .
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+2NC.
Conduit opening: G1/2.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV statuus display function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV MK3P-I DC125.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput MK3P-I DC125.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
MK3P-I DC125 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MK3P-I DC125&select=5