Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+1NC/1NO
M7E-02UR2-G
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available M7E-02UR2-G.
Key holding force of 1,300 N minimum .
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Name: Temperature Sensor Module.
Model: C200H-TS101.
Temperature sensor: RTD (JPt 100 Ω.).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected) M7E-02UR2-G. Appearance: T-shaped, slot center 10 mm .
Sensing method: R-shaped.
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: Incident light.
Model: NPN output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity.
Series includes models that enable switching between,
dark-ON and light-ON operation.
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for dark-ON,
operation are also available.
A wide range of variations in eight different shapes.
Flexible robot cable is provided as a standard feature. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 macchines to support a variety of sensorss M7E-02UR2-G.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eeexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
M7E-02UR2-G Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=M7E-02UR2-G&select=5