Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45) .
Cable length: 10 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Function name: 3 phase 200V.
Power: 11KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage) .
Built in brake unit (brake resistance needs to be matched) M16-AW-5.
Weight: 5
M16-AW-51KG.
Dimension (w * h) 296mm *:180.
Outline dimension (deep):175mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control M16-AW-5.
High starting torque: 0.5Hz up to 200% .
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Product name: N@@S1- type CPU Units with 60 I/O Points.
Specifications: Power Supply, DC24V; Inputs, 36; Outputs, 24;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): -- M16-AW-5.
Current consumption: 5 V, 0.31A; 24 V,0.02A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Model : C500-PS223-E.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operationss M16-AW-5.
Relays contacts for poweer ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators . Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teempperature fuse prevents internal burning due to,
triac or relay malfunctions M16-AW-5.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.
M16-AW-5 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=M16-AW-5&select=5