Actuator: Fork lever lock (left operation).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available LY2 DC125. )
M12-connector models are also available, saving on labor and,
simplifying replacement
LY2 DC125
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC LY2 DC125. Appearance: Shielded, M30 .
Sensing distance: 12 mm.
Output configuration: DC 2-wire (polarity).
Operation mode: NC.
Proximity Sensor Ideal for the Food and Beverage Industry. Supply voltage: 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: DPDT.
Long-time range model(0.1 min to 10 h).
Miniature Timer with Multiple Time Ranges,
and Multiple Operating Modes LY2 DC125.
UL listed when used with a Push-In Plus Terminal Block Socket .
Conforms to CSA, CE Marking, LR, and CCC.
Black design with power supply terminals on top and contact output,
terminals on bottom.
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock. Operating modes: Star-delta Timer.
Supply voltage: 12 VDC.
Control output: Contact outputs Delta circuit: SPDT, Star circuit: SPDT.
Set two time ranges between 1 and 120 s with one Timer.
Models with 240 to 440-VAC power supply added to series. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 200/220 VAC/VDC.
Pushbuutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2 LY2 DC125.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detaachhable Switch LY2 DC125.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1.
LY2 DC125 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=LY2 DC125&select=5