Type: rectangle.
Screen mode: 2 short axis segmentation.
Light way: LED.
Power supply voltage: DC24V.
Operating part of the left color: yellow.
Operation Department right color: red.
Square 40mm body of the indicator light series.
The same type as the A3S series button switch.
Easy to install from the front panel and no tools to carry out the lamp replacement KS1-ANSW90. Terminal type: Exposed-lead Models
KS1-ANSW90
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work KS1-ANSW90.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): No KS1-ANSW90.
Rated input voltage: DC, 24V .
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.080 A; 60 Hz, 0.070 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2200 r/min; 60 Hz, 2500 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 25.0 Pa; 60 Hz, 32.0 Pa.
Noise: 50 Hz, 26 dB; 60 Hz, 29 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Pllastic-bladed models (44 ttype) and metal-bladed models,
(28 type) included in series KS1-ANSW90.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffieed safety standards depend on the,
product KS1-ANSW90. Check the information given for available models of Axial fans and,
the information in Characteristics.
KS1-ANSW90 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=KS1-ANSW90&select=5