Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models . )
Sealing characteristics that meet IEC IP67 degree of protection K8AB-VS3 200/230VAC.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
K8AB-VS3 200/230VAC
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables K8AB-VS3 200/230VAC.
Multiple mounting possible with Switches with Plungers .
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Continuation of the E6B2 high cost, value also have more choice.
E6B3, E6C4 blockbuster debut! Complementary output of the first starting high anti interference K8AB-VS3 200/230VAC.
40mm diameter, shaft diameter of phi 8mm universal, with strong axial load capacity.
50mm diameter, shaft diameter of phi 10mm rugged, with strong axial load capacity,
At the same time, the use of IP65 anti drip, anti oil structure.
E6B2 complementary output will be issued over the same period.
Connection length to reach a full 30m!
Resolution (pulse / rotation):10~3600P/R.
Power supply voltage: DC12 ~ 24V
Consumption current: 100mA below.
Output state: complementary output.
Maximum response frequency: 100kHz.
Output phase difference: A phase, B phase difference 90 plus or minus 45.
Starting torque: M / 10mN below (at room temperature).
Maximum allowable speed: 6000r/min.
Axial force: radial...... 80N, axial...... 50N. Number of beams: 32.
Protective height: 640mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makkes it easy,
to set functions K8AB-VS3 200/230VAC.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions K8AB-VS3 200/230VAC.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
K8AB-VS3 200/230VAC Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K8AB-VS3 200/230VAC&select=5