Required for Analog Input and Output Units: For one Analog Unit.Appearance: M8.
Sensing distance: 1.5 mm.
Connection method: M12 Connector Models .
Cable specifications: --.
Operation mode : NC .
Pin arrangement: 1: +V, 3: 0 V,2: Control output.
Applicable connector code: D.
Model: NPN output .
Your Search for Proximity Sensors K3NX-VD1A-B4.
Starts with the World-leading.
Performance and Quality of the E2E
K3NX-VD1A-B4
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil K3NX-VD1A-B4.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work K3NX-VD1A-B4.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Supply voltage: 24 VAC; 12, 24 VDC.
Time-limit contact: DPST-NO.
Short-time range model (0.1 s to 10 min).
Ultra-slim Timer for G2R Relay Socket.
Pin configuration compatible with G2R Relay and mounts to the,
P2R/P2RF Socket.
Standard multiple time ranges and multiple operating modes.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt,
age, and EMC Directives. Size: 48 * 48mm, terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV sttate display function, tto see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV K3NX-VD1A-B4.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm fflexible contact output K3NX-VD1A-B4.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
K3NX-VD1A-B4 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=K3NX-VD1A-B4&select=5