LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
K3MA-L-C24VAC/VDC
No PHOTO
OMRON K3MA-L-C24VAC/VDC
Number of beams: 32.
Protective height: 299mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions . Number of beams: 10.
Protective height: 225mm K3MA-L-C24VAC/VDC.
Model: PNP output.
Basic Type with a combination of K3MA-L-C24VAC/VDC
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Fitting materials: Stainless steel (SUS304) K3MA-L-C24VAC/VDC.
Count: 1 .
Accessories: Description,Slotted/Phillips screws M3 × 8,
(with spring and plain washers);
Material, Stainless steel (SUS304);
Count, 2 .
Applicable sensor (mounting pitch on sensor side): E3Z pre-wired model.
Page: Dimensions, 13. Power supply voltage: 5 to 12 VDC.
Output configuration: Voltage output.
Resolution (pulses/rotation): 300, 360, 500, 600, 720, 800, 1,000, 1,024;
1,200, 1,500, 1,800, 2,000, 2,048; 2,500, 3,600 K3MA-L-C24VAC/VDC.
Hollow-shaft Encoder.
Incremental model.
External diameter of 40 mm.
Resolution of up to 3,600 ppr.
Slim design at only 26 mm thick. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 15 V.
Output current: 2.4 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/6000-W models) K3MA-L-C24VAC/VDC.
Safetty standards: UL 508/60950-1, cUL CSA C22 .2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply K3MA-L-C24VAC/VDC. ).
K3MA-L-C24VAC/VDC Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=K3MA-L-C24VAC/VDC&select=5


...more relevant model market price >>>>
Related products
OMRON
Temperature Meter
K3MA-L-C AC/DC24V
OMRON Temperature Meter K3MA-L-C AC/DC24V
Input type: Platinum-resistance thermome
OMRON
Temperature Meter
K3MA-L-C AC100-240V
OMRON Temperature Meter K3MA-L-C AC100-240V
Input type: Platinum-resistance thermome