Size: 48 x 48mm.
Body: terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - J-7-V2.
Event input points: -.
Transfer output: -
J-7-V2
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0 J-7-V2. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer J-7-V2. 4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultShape of box: With flange .
Actuator: Roller plunger (with a 6.8-dia. roller).
Conduit: Two on the side.
A New Monoblock Multiple Limit Switch.
Incorporating a Head Box with a Tough.
Head and Ensuring High Sealing.
Performance and a Mechanical.
Durability of 5,000,000 Operations.
Used for the sequential control of a variety of engineering.
machines and belt conveyor lines.
Built-in oil filter shuts out oil and water.
Approved by EN, IEC (Ground terminal models only.) and,
CCC (Chinese standard). Ask your OMRON representative,
for information on approved models.
Ground terminal models bear the CE mark. Number of beams: 16.
Protective height: 480mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Moddule (PDM) makes it easy,
to set functions J-7-V2.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions J-7-V2.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
J-7-V2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=J-7-V2&select=5