Appearance: Square/Projection type A22-C.
Output: SPST-NO + SPST-NC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks H7CN-XLNM DC24.
Finger protection mechanism on Switch Unit provided as a standard feature
H7CN-XLNM DC24
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models) H7CN-XLNM DC24.
IP65 (lighted models). Size: 48 x 96mm .
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use H7CN-XLNM DC24.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 3.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA coonnectors meet IP67 reequirements and ensure a,
94V-0 fire retardant rating H7CN-XLNM DC24.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnnector Assembly: Crimping, soldering, and screw-on H7CN-XLNM DC24.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
H7CN-XLNM DC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H7CN-XLNM DC24&select=5