H5S-FB-31 DC24
No PHOTO
next one: OMRON H5S-FB
Last one: OMRON H5S-WA2
OMRON H5S-FB-31 DC24
Model : CVM1D-BI102.
10-slot.Output: DPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28 . 5 mm, the smallest class in the industry H5S-FB-31 DC24.
Detachable Switch.
The same contacts can be used for both standard loads and microloads H5S-FB-31 DC24
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three H5S-FB-31 DC24.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) .
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation H5S-FB-31 DC24.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easiily because operation time,
is indicated from the start of operation H5S-FB-31 DC24.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions H5S-FB-31 DC24. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
H5S-FB-31 DC24 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=H5S-FB-31 DC24&select=5