Model: C200HW-ME08K.
Capacity: 8K words.Appearance: Knob-type Selector Switch A22W,
LED lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Automatic.
Output: SPST-NO.
Operating voltage: 24 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); A (blue) .
Install in 22-dia. or 25-dia. Panel Cutout H3JA-8A AC24 3S.
Lever for easily mounting and removing the Switch Unit
H3JA-8A AC24 3S
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models) H3JA-8A AC24 3S.
IP65 (lighted models). Size: 48 x 96mm .
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use H3JA-8A AC24 3S.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. CPU Unit: CP1L-EM CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs onnly);
Power supply, DC power supply; Output method, Transistor output(sourcing);
Inputs, 18; Output, 12 H3JA-8A AC24 3S.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CCP11L-L" has a standard-feature peripheral USB port H3JA-8A AC24 3S.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams.
H3JA-8A AC24 3S Operation manual/Instructions/Model selection sample download link: