LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
H3CR-HRL DC100-125 S
No PHOTO
OMRON H3CR-HRL DC100-125 S
The type of the drive lever: one way action roller rocker type (horizontal action).
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (2NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) H3CR-HRL DC100-125 S.
Forced open action structure H3CR-HRL DC100-125 S
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC H3CR-HRL DC100-125 S.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2 .
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement H3CR-HRL DC100-125 S.
Certified for EN 60947-5-1. Cable Specifications: PVC .
Cable connection direction: L-shaped.
No. of cable cores: 4.
Cable outer diameter: 5.4 mm dia.
Cable core cross-sectional area: 0.34 mm.
Cable length: 2 m.
LED: PNP.
Minimum order: 1.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 2.2 kW (11.1 A), 200 to 220 VAC.
Soft-start/stop Funnction Starts annd Stops H3CR-HRL DC100-125 S.
Three-phase Motors Smoothly and.
Economically.
Function like an inverter by holding down the starting current.
Comply with UL, CSA, IEC (400-V models only), and JEM.
requirements.
Mount with screws or to DIN tracks.
Compact monobloockk construction for the G3J-T217BL H3CR-HRL DC100-125 S.
(W: 100 × H: 100 × D: 110 mm) with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
H3CR-HRL DC100-125 S Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=H3CR-HRL DC100-125 S&select=5


...more relevant model market price >>>>
Related products