Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Top plunger, Adjustable.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) .
Wide standard operating temperature range:
-40°C to +100°C (standard type)
G7L-2A-P DC24
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model G7L-2A-P DC24. ) Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported G7L-2A-P DC24.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Cable core number: 4.
Cable lead direction: straight line type.
Cable length: 10m.
Save time, save maintenance cost,
With a waterproof connector environment and strong tolerance of FA.
For IP67, the FA 94V-0 connector small special flammability.
The wiring system makes the device more maintainable connector,
And reduce the downtime of equipment.
Introduction of connector and modular connector with cable.
A modular connector crimping type, welding type, screw connection type 3.
With the cable connector is obtained UL certification of products.
According to IEC61076-2-101 (IEC60947-5-2), NECA4202. Safety outputs *3: Instantaneous, 2(Semiconductor);
OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 2(Semiconductor); Outputs, 2(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 150 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control syystem setup G7L-2A-P DC24.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unnitt joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set G7L-2A-P DC24.
-Two logical AND connection inputs.
G7L-2A-P DC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G7L-2A-P DC24&select=5