Power supply voltage: 100 to 240 VAC.
Output: Relay.
Timer function: No.
Features: Single-function with one input/output (two circuits).
Offers High-speed Input Response of,
0.1 ms and Equipped with Built-in Timer,
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Lineup includes the S3D2-BK with flip-flop functions convenient for,
level control, the S3D2-AKD/CKD/CCD with 24-V power supply, and,
the S3D2-DK/EK with one input/output OFF-delay (two circuits),
useful for load control and lamp display,
Power source for the Sensor can be supplied up to 200 mA
G6Z-1PE-A DC12
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available G6Z-1PE-A DC12. Rated input voltage: 3-phase 3-wire mode, 380, 400, 415, or 480 VAC .
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase loss in three,
phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load) G6Z-1PE-A DC12.
World-wide power specifications supported by one unit .
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Optical system: diffuse type.
Detection distance: 600 positive and negative 350mm.
Beam shape: linear beam.
Beam diameter: 16mm * 0.3 M.
Resolution: 8 M.
Cable length: 2m. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see thhe state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV G6Z-1PE-A DC12.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation G6Z-1PE-A DC12.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
G6Z-1PE-A DC12 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G6Z-1PE-A DC12&select=5