Sensor type: 2 wire DC type 1 - 4 / 3 - 4 non polarity.
Input points: 8.
The I/O sensor connector for centralized wiring,
And the province of the number of processes, strong environmental resistance as the goal,
The outer control relay box.
Compact and strong centralized wiring trunk box conforming to IP67 .
The corresponding sensing I/O connector mode proximity switch, limit switch,
Photoelectric switch
G6E-134P-ST-US DC5
With the power to show LED, action shows LED.
The installation dimensions are the same and are not related to the number of input points,
Therefore, the addition of a simple exchange.
A series of sensors with self diagnostic features are added to the product G6E-134P-ST-US DC5. Output: SPDT.
Lighting: LED (with built-in reduced-voltage lighting function) .
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry G6E-134P-ST-US DC5.
Detachable Switch.
The same contacts can be used for both standard loads and microloads .
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 30W.
Output voltage: 24V.
Output current: 0.65A.
Alarm output: -.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 3000/600/1500W outpuut terminals)
Support finger touch protection to prevent electric shock G6E-134P-ST-US DC5.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable wheen the fan is replaced by the customer G6E-134P-ST-US DC5. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
G6E-134P-ST-US DC5 Operation manual/Instructions/Model selection sample download link: