Type: Flat Cable.
Terminal Block: Terminal block with M3.5 screws.
Connector: Flat Cable Connectors*1.
No. of poles: 20.
Simplifies Connector and terminal,
block replacement, and requires less,
in-panel wiring.
Mount to DIN Track or via screws.
MIL Flat Cable Connectors and Multi-pole, Square,
Connectors are standard .
Terminal blocks available with either M3 or M3 ZC-Q2255-MR VCT 5M. 5 screws.
Connecting Cables for Programmable Controllers,
available (sold separately)
ZC-Q2255-MR VCT 5M CVM1-CL Accessory CONTROL MODULE LINK FIBER CVM1-CLK12.Cable: With cable.
Connector: Connectors on both cable ends.
Cable length L: 3 m.
Minimum order: 5.
Small Round Water-resistive ZC-Q2255-MR VCT 5M.
Connectors.
Water-resistive, compact connector meets IP67 requirements .
Conventional M8 screw-mounting models are available along with,
S8 snap-in models that connect and disconnect with one touch.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles. Input capacity: 16 points.
Internal I/O common: PNP ZC-Q2255-MR VCT 5M.
ON voltage: 15 VDC min. (between each in,
put terminal and the G terminal) .
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 16 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 150 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard ee-CON connectors ZC-Q2255-MR VCT 5M.
A common terminal is provided for,
each connector .
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswiitch and with tool software ZC-Q2255-MR VCT 5M.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
ZC-Q2255-MR VCT 5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=ZC-Q2255-MR VCT 5M&select=5