Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- Y92S-37.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
Y92S-37 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 Y92S-37. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks .
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter Y92S-37.
Switch the PV display between three colors .
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Classification: the built-in CR components (only AC220/240V, AC200/220V, AC100/110V, AC110/120V).
Contact form: DPDT.
Structure: insert / solder terminal.
Indicator: with LED indicator light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: AC6V AC6V, MY2-J on behalf of the rated voltage of the coil.
Upgraded version of the small power relay, there are a variety of models, suitable for a variety of sequential control and power applications. Power ratings: 120 W.
Input voltage: 2-phase and 3-phase, 380 to 480 VAC, 450 to 600 VDC.
Output Voltage: 24 V.
Output current: 5 A.
Boost Current: 6 A.
Worldwide 3-phase Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Wide input range for worldwide applications:
380 to 480 VAC (320 to 576 VAC).
Possible for 2-phase input usage*:
3880 to 480 VAC (340 to 576 VACC) Y92S-37.
When using the 960 W at 2-phase input, the power rating is 768 W.
DC input can be available*:
450 to 600 VDC (450 to 810 VDC).
Excluding 960 W.
High efficiency 91% typ. at 480 W model.
Wide operation temperature range: –40 to 70°C.
Poweer Boost function at 120% Y92S-37.
Meets LR maritime standards.
EMS: Conforms to EN 61204-3.
EMI: EN61204-3 Class B.
RoHS Compliant.
Three years Warranty!
Y92S-37 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=Y92S-37&select=5