E32-A01 type: special beam type; liquid level detection,
Specialty: when there is liquid into the light, not susceptible to the effects of bubbles and water droplets,
Bending radius (mm): R4.
Fiber element for meeting diversified needsPower ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1 .
Output voltage: 24 V XS2G-D425.
Output current: 3.75 A.
Alarm output *2: Sourcing
XS2G-D425
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards XS2G-D425.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards XS2G-D425. ) Direction of Operation Key insertion: Horizontal .
Cable length: 1 m.
2NC/1NO (Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact.
construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock.
IP67 degree of protection. Using terminal, saving wiring and working hours.
Using a press connector to achieve individual wiring.
The terminal can realize the space saving.
The driving rod has 2 mounting directions, and the switch is installed with a large degree of freedom.
And SS ultra small micro switch installation spacing consistent. Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,3000 N XS2G-D425.
It is possible to chhange the key insertion point .
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk SSafety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames XS2G-D425.
The plastic material makes the Slide Key suitable,
for lightweight doors.
XS2G-D425 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=XS2G-D425&select=5