Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.130 A; 60 Hz, 0.110 A .
Rated input: 50 Hz, 20 W; 60 Hz, 18 W.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 2.6 m3/min; 60 Hz, 3 . 0 m3/min.
Maximum static pressure: 50 Hz, 66 XS2F-D421-GD0-TR. 6 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB
XS2F-D421-GD0-TR
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series XS2F-D421-GD0-TR.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Size: 1/8 DIN 48 × 96 × 78(W × H × D) XS2F-D421-GD0-TR.
Power supply voltage: 100 to 240 VAC .
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Voltage output(for driving SSR).
Functions: Heater burnout, No; Mounting option units, Yes.
Previous model: E5EZ-Q3 + E53-AZM .
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 macchines to support a variety of sensorss XS2F-D421-GD0-TR.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eeexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
XS2F-D421-GD0-TR Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XS2F-D421-GD0-TR&select=5