Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry .
Detachable Switch.
The same contacts can be used for both standard loads and microloads XR2A-1611-N.
Easy-to-wire terminal arrangement
XR2A-1611-N
Certified for EN 60947-5-1. Stability detection without fear of external interference.
Infrared beam design, anti foreign body blocking ability.
Reduce the chance of false action caused by dust and dirt.
Good environmental resistance XR2A-1611-N.
Using a unique optical design, environmental illumination up to 100kLx .
Protection structure to achieve IP67, waterproof and dust.
Convenient installation.
3 installation methods for selection. Improved update. Reduce standby power consumption, and then achieve lightweight.
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products XR2A-1611-N. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance.
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible.
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
Relay unit.
Product Name: 61F-11_ unit * 1.
Purpose: long distance use (4km). Power supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 18 points.
Outputs points: 12 points.Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked eeasily because operation time,
is indicated from the start of operation XR2A-1611-N.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions XR2A-1611-N. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
XR2A-1611-N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XR2A-1611-N&select=5