Name: Color LCD Monitor.
Easy-to-use Windows®-based software that can provide,
more sophisticated functionality and capability to the,
F150-3 using a drag-and-drop, flow-chart like setup envi,
ronment requiring no programming skills. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V) .
Shell color: black XM7A-0441.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling
XM7A-0441
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products XM7A-0441.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors XM7A-0441.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultUnit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100, Pt50, Ni508.4.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.07A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,,
have enabled major savinngs in cost and space compared,
with previous systems XM7A-0441.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems XM7A-0441.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
XM7A-0441 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XM7A-0441&select=5