Setting: simulation settings.
Indication mode: no indication.
Adjustment mode: ON/OFF action.
Output: relay.
Input: component interchange type thermistor.
The size of the DIN48 to achieve the simulation set, low cost.
The most small and realize the low cost of.
Proportional (P) action in the regulation mode .
And the reset function is added XG8W-2434.
Through the installation of the adapter can be continuously close
XG8W-2434
The installation of DIN guide rail and panel mounting can be carried out by means of insertion. Temperature range: 150°C to 300°C.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work XG8W-2434.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Model: P7TF (frontmounting), page 12s.
Approx: 28 g.
Number of pins: 5 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection XG8W-2434.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Model: OCGR-H (51G).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to thee generator and the electriic side / internal tributaries XG8W-2434.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiinee the direction of the sudden drop in the voltage to 0 of the short-circuit accident XG8W-2434.
2 stage cross terminal stand with cover with convenient wiring.
XG8W-2434 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XG8W-2434&select=5