Type: 1a1b welding terminal.
Shape: square.
Type: General load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC12V.
Operation Department color: red.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch .
Miniaturization, operation feel good WLGCA2-55LD-M1GJ-N. Input terminals: Compact slotted screw terminals (detachable)
WLGCA2-55LD-M1GJ-N
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC WLGCA2-55LD-M1GJ-N.
A New-concept SSR with Built-in.
Current Transformer .
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws WLGCA2-55LD-M1GJ-N.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable) .
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Actuator: Plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made witth CompoNet WLGCA2-55LD-M1GJ-N.
Wiriing material cost can be reduced .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee . WLGCA2-55LD-M1GJ-N.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
WLGCA2-55LD-M1GJ-N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WLGCA2-55LD-M1GJ-N&select=5