Number of beams: 15.
Protective height: 720mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions . Output: DPDT.
Lighting: LED without Voltage Reduction Unit V-163-1A6.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white
V-163-1A6
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch V-163-1A6.
The same contacts can be used for both standard loads and microloads .
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters V-163-1A6.
Detects SSR short-circuit failures .
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Free change detection direction.
Easy to use small cube type.
Can change the direction of detection according to the position of the front and side (15 degree).
Type: cube detection variable way / DC type connector.
Shape: shield.
Detection distance: 20mm.
Output status: NO+NC NPN (two kinds of output). Control power supply voltage: 200/220 VAC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or oovercur,
rent using currennt converter V-163-1A6.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrsee current detection V-163-1A6.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
V-163-1A6 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=V-163-1A6&select=5