Control output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance UMYM5-1000-1250.
Handles More Applications.
The white PV display with a height of 15
UMYM5-1000-12502 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other UMYM5-1000-1250. Control output 1: Voltage output .
Control output 2: --.
Auxiliary output: Three.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications UMYM5-1000-1250.
The white PV display with a height of 15 . 2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.
Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Pre-wired.
Sensing distance: 200 mm.
Functions: Timer Self Diagnosis Turbo.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 0.5 to 1 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarmm signal UMYM5-1000-1250.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out .
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with boothh single-phase and three-phase heaters UMYM5-1000-1250.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
UMYM5-1000-1250 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=UMYM5-1000-1250&select=5