Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work TL-T2F2 5M.
Ideal for the thermal input devices of Temperature Controllers
TL-T2F2 5M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Power ratings: 50 W.
Output voltage: 5 V.
Output current: 10 A TL-T2F2 5M.
Boost current: 15 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup .
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No TL-T2F2 5M. 60950-1, EN 50178,
and EN 60950-1 .
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Type: H7CX-A Series.
Classification: Preset counter/Tachometer.
Configuration: 1-stage preset counter, 2-stage preset counter,
Total and preset counter, Batch counter, Dual counter, Twin counter, Tachometer.
External connections: Screw terminals.
Settings: 2-stage.
Display digit: 6 digits.
Outputs: Transistor output (DPST).
Power supply voltage: 100 to 240 VAC.
Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readabiliity with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models TL-T2F2 5M.
The present value display characters can be switched between red,
green, and orange.
Safety and Reliability.
New set value limit and counter functions have been added.
Other Features.
FFront Panel can be changed to white or light gray TL-T2F2 5M.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series.
TL-T2F2 5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=TL-T2F2 5M&select=5