Actuator: Sealed top-roller plunger.
Hermetic; Molded terminals, -139 models.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches .
Standard-feature gold-clad crossbar contacts provide high reliability SGE-365-3-1290L 00300M-00300F.
Applicable to either standard loads or microloads
SGE-365-3-1290L 00300M-00300F
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models SGE-365-3-1290L 00300M-00300F. Name: Basic Unit (temperature control) *1 .
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None SGE-365-3-1290L 00300M-00300F.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485 .
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Conneect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise SGE-365-3-1290L 00300M-00300F.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullatte the PID constants with the step,
response method SGE-365-3-1290L 00300M-00300F.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
SGE-365-3-1290L 00300M-00300F Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-365-3-1290L 00300M-00300F&select=5