Cable: PUR.
Cable core number (core): 4.
Cable outside diameter: 4.7mm.
Cable outlet direction: L type.
Cable length L:5m.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67.
FA small special connector flame retardant 94V-0.
The connector wiring system, convenient equipment maintenance,
Reduce equipment downtime SGE-245-5-3050L 03050C-03050F.
IEC61076-2-101 (IEC60947-5-2)
SGE-245-5-3050L 03050C-03050F
For LED products, can clearly confirm the status of the sensor action.
Name: On-site Flexible Rod Switch (integrated switch only).
Mounting method: Base mounting.
Easy on-site input on-the-move.
Incorporation of plastic rod actuator makes the Switch easy on hands SGE-245-5-3050L 03050C-03050F.
One-way operation:
Equipped with stopper so that operation is only possible from one direction .
Distinctive yellow used for the body.
Three different types of mounting are available.
Models with emergency-stop switch are available to suit the application. Appearance: Round/Half-guard type LED lighting,
(without Voltage Reduction Unit) A22L-H SGE-245-5-3050L 03050C-03050F.
Output: SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC .
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display functioon, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV SGE-245-5-3050L 03050C-03050F.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput SGE-245-5-3050L 03050C-03050F.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
SGE-245-5-3050L 03050C-03050F Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-245-5-3050L 03050C-03050F&select=5