Size: 48 * 48mm, terminal type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function SGE-225-4-1520 00500M.
Event input points: -.
Transfer output: -
SGE-225-4-1520 00500M
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure SGE-225-4-1520 00500M.
High resolution 5 bit display / can display 0 . 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV SGE-225-4-1520 00500M.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) .
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output load(See note 2.): 75 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor effectively absorbs external surges.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.Type: open type.
Structure: bottom mounting type.
Capacity: 50W.
Output voltage: 5V.
Output current: 10A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300//600/1500W outpput terminals)
Support finger touch protection to prevent electric shock SGE-225-4-1520 00500M.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhenn the fan is replaced by the customer SGE-225-4-1520 00500M. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
SGE-225-4-1520 00500M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-225-4-1520 00500M&select=5