Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Manual.
Output: SPST-NO + SPST-NO.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia . or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit SGE-225-2-4500 10000C.
Finger protection mechanism on Switch Unit provided as a standard feature
SGE-225-2-4500 10000C
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models) SGE-225-2-4500 10000C.
IP65 (lighted models). Actuator: Shaft.
Conduit size: 2-conduit; G1/2 .
Built-in switch mechanism: 3NC (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available SGE-225-2-4500 10000C.
Standardized gold-clad contacts provide high contact reliability .
Can be used with both standard loads and microloads. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the statee of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV SGE-225-2-4500 10000C.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation SGE-225-2-4500 10000C.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
SGE-225-2-4500 10000C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-225-2-4500 10000C&select=5