E32-T16P type: special beam type; region detection,
Specialty: regional width 11mm,
Shape / detection distance (mm): 1500; 1100; 750 (300),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.2) 3,
Fiber element for meeting diversified needsSpecification: three phase 200V .
Power: 2.2KW.
Maximum output voltage: three phase input voltage SGE-225-0-2240N 05000C-05000C.
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V
SGE-225-0-2240N 05000C-05000C
Cooling: forced air cooling.
Weight: 1.9kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ SGE-225-0-2240N 05000C-05000C.
3G3MZ series inverter for the application of frequency control and development .
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice SGE-225-0-2240N 05000C-05000C. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled majorr savinngs in cost and space compared,
with previous systems SGE-225-0-2240N 05000C-05000C.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems SGE-225-0-2240N 05000C-05000C.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
SGE-225-0-2240N 05000C-05000C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=SGE-225-0-2240N 05000C-05000C&select=5