Type of input: AC voltage input.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with .
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
SGE-225-0-0200N 02000C-02000C
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations SGE-225-0-0200N 02000C-02000C.
DevLock method: Solenoid lock .
Conduit size: PG13.5.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation SGE-225-0-0200N 02000C-02000C.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid .
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporrating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 SGE-225-0-0200N 02000C-02000C.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key fforr a swinging door are available SGE-225-0-0200N 02000C-02000C.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.