Output method: Relay.
Inputs: ---.
Outputs: 8.Appearance: Round/Full-guard type LED lighting,
(without Voltage Reduction Unit) A22L-G.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue) .
Install in 22-dia S8T-BUS13. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit
S8T-BUS13
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type S8T-BUS13.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models S8T-BUS13. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
ann alarm signal S8T-BUS13.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out .
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with boothh single-phase and three-phase heaters S8T-BUS13.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
S8T-BUS13 Operation manual/Instructions/Model selection sample download link: