Appearance: Shielded, M30.
Sensing distance: 8 mm.
Output configuration: DC 2-wire, (1)-(4) pin arrangement.
Model: Operation mode, NO.
Chip-immune Inductive.
Proximity Sensor.
Correct operation even with aluminum or iron chips sticking,
to the Sensor.
Only the sensing object is detected.
Pre-wired Smartclick Connector Models also available S8E1-05005B. Improved update. Reduce standby power consumption, and then achieve lightweight
S8E1-05005B
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance S8E1-05005B.
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible .
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
G1N type automatic water supply, both to prevent idling or water alarm function S8E1-05005B.
Package product name: 61F-G1N base * 1, 61F-11_ unit * 2 .
Purpose: long distance use (2km). Rated primary current: 600 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also usedd for classified standby and stopped power S8E1-05005B.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss . S8E1-05005B.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
S8E1-05005B Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=S8E1-05005B&select=5