Output: DPDT.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry .
Detachable Switch S82R-2322 AC200 30W 5V 24V.
The same contacts can be used for both standard loads and microloads
S82R-2322 AC200 30W 5V 24V
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC S82R-2322 AC200 30W 5V 24V.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 35 A, 100 to 240 VAC .
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks S82R-2322 AC200 30W 5V 24V.
DIN Track mounting types and screw mounting types are available .
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Size: 96 × 96 mm.
Control type: Position-proportional control(1 loop).
Control mode: Single-loop position-proportional control(See note.).
Outputs(control/transfer): Relay output(1 open, 1 close).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a singlle Controlller S82R-2322 AC200 30W 5V 24V.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
rooot calculation and broken-line approximation) S82R-2322 AC200 30W 5V 24V.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.
S82R-2322 AC200 30W 5V 24V Operation manual/Instructions/Model selection sample download link: